VALIDATION OF ASESULFAM ANALYSIS METHODS IN SWEETENER PRODUCTS AND CONTRIBUTION TO EXPOSURE OF DIABETIC PATIENTS AT THE KIARA HUSADA CLINIC BANDUNG

Food additives (FA) are components added to food to influence the nature or form of food. Acesulfame is one of the FA belongs to the functional class of sweeteners permitted in several categories of food products, including table top sweeteners. The aims of this study were to obtain an analyti...

Full description

Saved in:
Bibliographic Details
Main Author: Aulia Rahman, Adam
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/76470
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:76470
spelling id-itb.:764702023-08-15T15:00:38ZVALIDATION OF ASESULFAM ANALYSIS METHODS IN SWEETENER PRODUCTS AND CONTRIBUTION TO EXPOSURE OF DIABETIC PATIENTS AT THE KIARA HUSADA CLINIC BANDUNG Aulia Rahman, Adam Indonesia Theses Food Additives, Acesulfame, Table-Top Sweetener, High Performance Liquid Chromatography INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/76470 Food additives (FA) are components added to food to influence the nature or form of food. Acesulfame is one of the FA belongs to the functional class of sweeteners permitted in several categories of food products, including table top sweeteners. The aims of this study were to obtain an analytical method for determination of acesulfame in table top sweetener, data on acesulfame levels and estimation of acesulfame exposure in diabetic patients from this product. The validation parameters determined, include linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of analytical method using high performance liquid chromatography (HPLC). The precision and accuracy of the method are expressed as relative standard deviation (RSD) and percent of recovery of the determination of the standard added in the range of 80-120% of the actual concentration of acesulfame in the sample. The LOD and LOQ of the method were statistically calculated from the calibration curve. Exposure assessment was carried out by filling out questionnaires by diabetic patients as respondents using the food recall method. The results showed, the calibration curve of acesulfame has the equation of Y = 0.6654 X-0.002 and R2 value of 0.9991, relative standard deviation in the range of 0.38 - 3.9 %, percent recovery in the range of 91.2 - 94.8 %, as well as LOD and LOD of 1.54 ?g/mL and 4.68 ?g/mL, recpectively. Acesulfame exposure from products A and B were respectively 0.11 and 0.24 mg/kg bw/day, equivalent to 0.40 and 0.24% of the acceptable daily intake (ADI) of acesulfame of 15 mg/kg bw/day. Based on the overall results, it colud be concluded that the method for the determination of acesulfame in table top sweetener products was successfully obtained, the levels of asulfame in the product were 4.24 and 9.28 mg/g, and exposure of acesulfame in diabetic patients was not geater than its ADI value. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Food additives (FA) are components added to food to influence the nature or form of food. Acesulfame is one of the FA belongs to the functional class of sweeteners permitted in several categories of food products, including table top sweeteners. The aims of this study were to obtain an analytical method for determination of acesulfame in table top sweetener, data on acesulfame levels and estimation of acesulfame exposure in diabetic patients from this product. The validation parameters determined, include linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of analytical method using high performance liquid chromatography (HPLC). The precision and accuracy of the method are expressed as relative standard deviation (RSD) and percent of recovery of the determination of the standard added in the range of 80-120% of the actual concentration of acesulfame in the sample. The LOD and LOQ of the method were statistically calculated from the calibration curve. Exposure assessment was carried out by filling out questionnaires by diabetic patients as respondents using the food recall method. The results showed, the calibration curve of acesulfame has the equation of Y = 0.6654 X-0.002 and R2 value of 0.9991, relative standard deviation in the range of 0.38 - 3.9 %, percent recovery in the range of 91.2 - 94.8 %, as well as LOD and LOD of 1.54 ?g/mL and 4.68 ?g/mL, recpectively. Acesulfame exposure from products A and B were respectively 0.11 and 0.24 mg/kg bw/day, equivalent to 0.40 and 0.24% of the acceptable daily intake (ADI) of acesulfame of 15 mg/kg bw/day. Based on the overall results, it colud be concluded that the method for the determination of acesulfame in table top sweetener products was successfully obtained, the levels of asulfame in the product were 4.24 and 9.28 mg/g, and exposure of acesulfame in diabetic patients was not geater than its ADI value.
format Theses
author Aulia Rahman, Adam
spellingShingle Aulia Rahman, Adam
VALIDATION OF ASESULFAM ANALYSIS METHODS IN SWEETENER PRODUCTS AND CONTRIBUTION TO EXPOSURE OF DIABETIC PATIENTS AT THE KIARA HUSADA CLINIC BANDUNG
author_facet Aulia Rahman, Adam
author_sort Aulia Rahman, Adam
title VALIDATION OF ASESULFAM ANALYSIS METHODS IN SWEETENER PRODUCTS AND CONTRIBUTION TO EXPOSURE OF DIABETIC PATIENTS AT THE KIARA HUSADA CLINIC BANDUNG
title_short VALIDATION OF ASESULFAM ANALYSIS METHODS IN SWEETENER PRODUCTS AND CONTRIBUTION TO EXPOSURE OF DIABETIC PATIENTS AT THE KIARA HUSADA CLINIC BANDUNG
title_full VALIDATION OF ASESULFAM ANALYSIS METHODS IN SWEETENER PRODUCTS AND CONTRIBUTION TO EXPOSURE OF DIABETIC PATIENTS AT THE KIARA HUSADA CLINIC BANDUNG
title_fullStr VALIDATION OF ASESULFAM ANALYSIS METHODS IN SWEETENER PRODUCTS AND CONTRIBUTION TO EXPOSURE OF DIABETIC PATIENTS AT THE KIARA HUSADA CLINIC BANDUNG
title_full_unstemmed VALIDATION OF ASESULFAM ANALYSIS METHODS IN SWEETENER PRODUCTS AND CONTRIBUTION TO EXPOSURE OF DIABETIC PATIENTS AT THE KIARA HUSADA CLINIC BANDUNG
title_sort validation of asesulfam analysis methods in sweetener products and contribution to exposure of diabetic patients at the kiara husada clinic bandung
url https://digilib.itb.ac.id/gdl/view/76470
_version_ 1822007992202035200