Fabrication of 3C-silicon carbide membranes: Towards development of novel microdevices for biomedical applications
Link to publisher's homepage at http://ieeexplore.ieee.org/
Saved in:
Main Authors: | , , , , , , , |
---|---|
Other Authors: | |
Format: | Working Paper |
Language: | English |
Published: |
Institute of Electrical and Electronics Engineers (IEEE)
2012
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/21405 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaysia Perlis |
Language: | English |
id |
my.unimap-21405 |
---|---|
record_format |
dspace |
spelling |
my.unimap-214052012-10-18T07:54:10Z Fabrication of 3C-silicon carbide membranes: Towards development of novel microdevices for biomedical applications Nashrul Fazli, Mohd Nasir Charan, M. Shah Leech, Patrick William Reeves, Geoffrey K. Pirogova, Elena Istivan, Taghrid S Tanner, Philip G. Holland, Anthony Stephen nashrul@unimap.edu.my Silicon Carbide Microfabrication Micromachining Membrane Wet etching Reactive ion etching X-Ray Photoelectron Spectroscopy (XPS) Biomedical microdevices Link to publisher's homepage at http://ieeexplore.ieee.org/ 3C-SiC is currently under intense study as a potential material for implantable low power blood pressure sensing due to its biocompatibility. In this work, we present and discuss the fabrication processes for n-type 3C-SiC membranes using epitaxial SiC layers with thicknesses of 0.285 and 0.95 μm on Si substrates (650 μm). Membranes of n-type SiC with dimensions of 0.5×0.5 cm2 were successfully fabricated using the described method for both thicknesses. We also report the fabrication of larger area membranes (1.5× 1.0 cm2) using the 0.95 μm epitaxial layer. The thicker membrane was able to flex when probed using a micromanipulator electrical probe, however, the 0.285 μm membrane could not support the same small force. The ability to fabricate patterns of aluminum on the surface of the thicker membrane suggests future applications of large 3C-SiC membranes in microfabrication technology for biomedical microdevices. For electrical characterization, arrays of metal patterns were made on the 3C-SiC. Surface modification due to reactive ion etching (RIE) process had significant impact on the electrical properties of the sample. X-Ray Photoelectron Spectroscopy (XPS) was used to investigate surface modification due to RIE. The effect of reactive ion etching is expected to modify the biocompatibility of the 3C-SiC as a potential biomaterial. 2012-10-18T07:54:10Z 2012-10-18T07:54:10Z 2012-02-27 Working Paper p. 589-593 978-145771989-9 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6178985 http://hdl.handle.net/123456789/21405 en Proceedings of the International Conference on Biomedical Engineering (ICoBE 2012) Institute of Electrical and Electronics Engineers (IEEE) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Silicon Carbide Microfabrication Micromachining Membrane Wet etching Reactive ion etching X-Ray Photoelectron Spectroscopy (XPS) Biomedical microdevices |
spellingShingle |
Silicon Carbide Microfabrication Micromachining Membrane Wet etching Reactive ion etching X-Ray Photoelectron Spectroscopy (XPS) Biomedical microdevices Nashrul Fazli, Mohd Nasir Charan, M. Shah Leech, Patrick William Reeves, Geoffrey K. Pirogova, Elena Istivan, Taghrid S Tanner, Philip G. Holland, Anthony Stephen Fabrication of 3C-silicon carbide membranes: Towards development of novel microdevices for biomedical applications |
description |
Link to publisher's homepage at http://ieeexplore.ieee.org/ |
author2 |
nashrul@unimap.edu.my |
author_facet |
nashrul@unimap.edu.my Nashrul Fazli, Mohd Nasir Charan, M. Shah Leech, Patrick William Reeves, Geoffrey K. Pirogova, Elena Istivan, Taghrid S Tanner, Philip G. Holland, Anthony Stephen |
format |
Working Paper |
author |
Nashrul Fazli, Mohd Nasir Charan, M. Shah Leech, Patrick William Reeves, Geoffrey K. Pirogova, Elena Istivan, Taghrid S Tanner, Philip G. Holland, Anthony Stephen |
author_sort |
Nashrul Fazli, Mohd Nasir |
title |
Fabrication of 3C-silicon carbide membranes: Towards development of novel microdevices for biomedical applications |
title_short |
Fabrication of 3C-silicon carbide membranes: Towards development of novel microdevices for biomedical applications |
title_full |
Fabrication of 3C-silicon carbide membranes: Towards development of novel microdevices for biomedical applications |
title_fullStr |
Fabrication of 3C-silicon carbide membranes: Towards development of novel microdevices for biomedical applications |
title_full_unstemmed |
Fabrication of 3C-silicon carbide membranes: Towards development of novel microdevices for biomedical applications |
title_sort |
fabrication of 3c-silicon carbide membranes: towards development of novel microdevices for biomedical applications |
publisher |
Institute of Electrical and Electronics Engineers (IEEE) |
publishDate |
2012 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/21405 |
_version_ |
1643793393144299520 |