Polymer microfluidic devices : sealing and lamination of topas microfluidic devices by thermal bonding

This project aims to evaluate and optimize the thermal bonding parameters in order to fabricate TOPAS Cyclic Olefin Copolymer (COC) micro-channeled devices with good replication accuracy that can withstand the pressures subjected by fluid flow during applications. Micro-channeled plates and b...

Full description

Saved in:
Bibliographic Details
Main Author: Li, Aaron Shi Wei.
Other Authors: Yue Chee Yoon
Format: Final Year Project
Language:English
Published: 2010
Subjects:
Online Access:http://hdl.handle.net/10356/40622
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-40622
record_format dspace
spelling sg-ntu-dr.10356-406222023-03-04T19:28:58Z Polymer microfluidic devices : sealing and lamination of topas microfluidic devices by thermal bonding Li, Aaron Shi Wei. Yue Chee Yoon School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering::Fluid mechanics This project aims to evaluate and optimize the thermal bonding parameters in order to fabricate TOPAS Cyclic Olefin Copolymer (COC) micro-channeled devices with good replication accuracy that can withstand the pressures subjected by fluid flow during applications. Micro-channeled plates and blank plates of the different TOPAS COC graded raw materials are produced by an injection molding process. Injection molding is a manufacturing technique that is widely used for mass production of parts and some of the advantages of this process includes high efficiency and low costs. There are numerous techniques and methods of sealing and lamination of micro-fluidic devices and one such method is thermal bonding. Firstly, parameters were determined for optimization in thermal bonding. They are bonding temperature, time and pressure. With the different sets of parameters obtained, burst pressure analysis is carried out to determine the critical burst pressure achieved for each set of parameters. Repeatability tests were carried out to show that the optimized parameter values for each set of material have been established. After burst pressure analysis is carried out, the plates are de-laminated. The confocal imaging profiler was used to analyze all samples and gather data on the profiles of the micro-channels before and after thermal bonding. These additional data provides a comparison for the study on the behavior of the micro-channels under the different sets of parameters and materials. A write-up on the problems faced throughout the project as well as some suggestions on the improvements for future study will be produced. Lastly, a conclusion will be made to sum up on the experiences and lessons learnt throughout this project. Bachelor of Engineering (Mechanical Engineering) 2010-06-17T02:44:17Z 2010-06-17T02:44:17Z 2010 2010 Final Year Project (FYP) http://hdl.handle.net/10356/40622 en Nanyang Technological University 90 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering::Fluid mechanics
spellingShingle DRNTU::Engineering::Mechanical engineering::Fluid mechanics
Li, Aaron Shi Wei.
Polymer microfluidic devices : sealing and lamination of topas microfluidic devices by thermal bonding
description This project aims to evaluate and optimize the thermal bonding parameters in order to fabricate TOPAS Cyclic Olefin Copolymer (COC) micro-channeled devices with good replication accuracy that can withstand the pressures subjected by fluid flow during applications. Micro-channeled plates and blank plates of the different TOPAS COC graded raw materials are produced by an injection molding process. Injection molding is a manufacturing technique that is widely used for mass production of parts and some of the advantages of this process includes high efficiency and low costs. There are numerous techniques and methods of sealing and lamination of micro-fluidic devices and one such method is thermal bonding. Firstly, parameters were determined for optimization in thermal bonding. They are bonding temperature, time and pressure. With the different sets of parameters obtained, burst pressure analysis is carried out to determine the critical burst pressure achieved for each set of parameters. Repeatability tests were carried out to show that the optimized parameter values for each set of material have been established. After burst pressure analysis is carried out, the plates are de-laminated. The confocal imaging profiler was used to analyze all samples and gather data on the profiles of the micro-channels before and after thermal bonding. These additional data provides a comparison for the study on the behavior of the micro-channels under the different sets of parameters and materials. A write-up on the problems faced throughout the project as well as some suggestions on the improvements for future study will be produced. Lastly, a conclusion will be made to sum up on the experiences and lessons learnt throughout this project.
author2 Yue Chee Yoon
author_facet Yue Chee Yoon
Li, Aaron Shi Wei.
format Final Year Project
author Li, Aaron Shi Wei.
author_sort Li, Aaron Shi Wei.
title Polymer microfluidic devices : sealing and lamination of topas microfluidic devices by thermal bonding
title_short Polymer microfluidic devices : sealing and lamination of topas microfluidic devices by thermal bonding
title_full Polymer microfluidic devices : sealing and lamination of topas microfluidic devices by thermal bonding
title_fullStr Polymer microfluidic devices : sealing and lamination of topas microfluidic devices by thermal bonding
title_full_unstemmed Polymer microfluidic devices : sealing and lamination of topas microfluidic devices by thermal bonding
title_sort polymer microfluidic devices : sealing and lamination of topas microfluidic devices by thermal bonding
publishDate 2010
url http://hdl.handle.net/10356/40622
_version_ 1759854315368873984