Design and development of an apparatus to aid in the detection of tuberculosis

In this project, the current method of handling the sputum specimens till diagnosis and the amount of risk exposure to the healthcare worker are studied. A new device to collect, process and analyse sputum samples of suspected TB patients has been designed and developed. This is especially useful fo...

Full description

Saved in:
Bibliographic Details
Main Author: Lo, Suan Theng.
Other Authors: Lim, Chu Sing
Format: Theses and Dissertations
Published: 2008
Subjects:
Online Access:http://hdl.handle.net/10356/6103
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
id sg-ntu-dr.10356-6103
record_format dspace
spelling sg-ntu-dr.10356-61032023-03-11T17:05:07Z Design and development of an apparatus to aid in the detection of tuberculosis Lo, Suan Theng. Lim, Chu Sing School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering::Bio-mechatronics In this project, the current method of handling the sputum specimens till diagnosis and the amount of risk exposure to the healthcare worker are studied. A new device to collect, process and analyse sputum samples of suspected TB patients has been designed and developed. This is especially useful for rapid screening purposes. This new collection device significantly reduces the risks and number of steps involved in detecting the class III bacteria. Master of Science (Smart Product Design) 2008-09-17T11:06:49Z 2008-09-17T11:06:49Z 2005 2005 Thesis http://hdl.handle.net/10356/6103 Nanyang Technological University application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
topic DRNTU::Engineering::Mechanical engineering::Bio-mechatronics
spellingShingle DRNTU::Engineering::Mechanical engineering::Bio-mechatronics
Lo, Suan Theng.
Design and development of an apparatus to aid in the detection of tuberculosis
description In this project, the current method of handling the sputum specimens till diagnosis and the amount of risk exposure to the healthcare worker are studied. A new device to collect, process and analyse sputum samples of suspected TB patients has been designed and developed. This is especially useful for rapid screening purposes. This new collection device significantly reduces the risks and number of steps involved in detecting the class III bacteria.
author2 Lim, Chu Sing
author_facet Lim, Chu Sing
Lo, Suan Theng.
format Theses and Dissertations
author Lo, Suan Theng.
author_sort Lo, Suan Theng.
title Design and development of an apparatus to aid in the detection of tuberculosis
title_short Design and development of an apparatus to aid in the detection of tuberculosis
title_full Design and development of an apparatus to aid in the detection of tuberculosis
title_fullStr Design and development of an apparatus to aid in the detection of tuberculosis
title_full_unstemmed Design and development of an apparatus to aid in the detection of tuberculosis
title_sort design and development of an apparatus to aid in the detection of tuberculosis
publishDate 2008
url http://hdl.handle.net/10356/6103
_version_ 1761781228300664832