Adaptive control for a one-link robot arm actuated by pneumatic muscles

Presently artificial pneumatic muscles are used in various applications due to their simple construction, lightweight and high force to weight ratio. However, controls of various mechanical systems actuated by pneumatic muscles are facing various problems. The parameters of the muscles are nonlinear...

Full description

Saved in:
Bibliographic Details
Main Authors: Tarapong Karnjanaparichat, Radom Pongvuthithum
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=67650700780&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60147
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-60147
record_format dspace
spelling th-cmuir.6653943832-601472018-09-10T03:48:17Z Adaptive control for a one-link robot arm actuated by pneumatic muscles Tarapong Karnjanaparichat Radom Pongvuthithum Biochemistry, Genetics and Molecular Biology Chemistry Materials Science Mathematics Physics and Astronomy Presently artificial pneumatic muscles are used in various applications due to their simple construction, lightweight and high force to weight ratio. However, controls of various mechanical systems actuated by pneumatic muscles are facing various problems. The parameters of the muscles are nonlinear and time-varying due to temperature change and the deterioration of the pneumatic muscle materials when the muscles are used for an extended period of time. Therefore, adaptive control is suitable to solve control problems for the pneumatic muscles since it can be designed to be independent of all system parameters and be able to adapt to certain changes of the system parameters. In this paper, we study the problem of adaptive output tracking for a one-link robot arm actuated by two opposing pneumatic muscle groups. The two muscle groups are arranged to simulate the physiological model of the bicep-tricep system. An adaptive controller is designed under the condition that all physical parameters, such as the pneumatic muscle coefficients, length of the arm, mass, moment of inertia and etc., are unknown. Under this condition, we can prove that closed-loop trajectory of the joint angle can follow any C1 signal and the angle error will be within a prescribed error in a finite time. Simulations are presented to demonstrate the robustness of our adaptive controller under serve changes of the system parameters. 2018-09-10T03:38:42Z 2018-09-10T03:38:42Z 2008-09-01 Journal 01252526 2-s2.0-67650700780 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=67650700780&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60147
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Biochemistry, Genetics and Molecular Biology
Chemistry
Materials Science
Mathematics
Physics and Astronomy
spellingShingle Biochemistry, Genetics and Molecular Biology
Chemistry
Materials Science
Mathematics
Physics and Astronomy
Tarapong Karnjanaparichat
Radom Pongvuthithum
Adaptive control for a one-link robot arm actuated by pneumatic muscles
description Presently artificial pneumatic muscles are used in various applications due to their simple construction, lightweight and high force to weight ratio. However, controls of various mechanical systems actuated by pneumatic muscles are facing various problems. The parameters of the muscles are nonlinear and time-varying due to temperature change and the deterioration of the pneumatic muscle materials when the muscles are used for an extended period of time. Therefore, adaptive control is suitable to solve control problems for the pneumatic muscles since it can be designed to be independent of all system parameters and be able to adapt to certain changes of the system parameters. In this paper, we study the problem of adaptive output tracking for a one-link robot arm actuated by two opposing pneumatic muscle groups. The two muscle groups are arranged to simulate the physiological model of the bicep-tricep system. An adaptive controller is designed under the condition that all physical parameters, such as the pneumatic muscle coefficients, length of the arm, mass, moment of inertia and etc., are unknown. Under this condition, we can prove that closed-loop trajectory of the joint angle can follow any C1 signal and the angle error will be within a prescribed error in a finite time. Simulations are presented to demonstrate the robustness of our adaptive controller under serve changes of the system parameters.
format Journal
author Tarapong Karnjanaparichat
Radom Pongvuthithum
author_facet Tarapong Karnjanaparichat
Radom Pongvuthithum
author_sort Tarapong Karnjanaparichat
title Adaptive control for a one-link robot arm actuated by pneumatic muscles
title_short Adaptive control for a one-link robot arm actuated by pneumatic muscles
title_full Adaptive control for a one-link robot arm actuated by pneumatic muscles
title_fullStr Adaptive control for a one-link robot arm actuated by pneumatic muscles
title_full_unstemmed Adaptive control for a one-link robot arm actuated by pneumatic muscles
title_sort adaptive control for a one-link robot arm actuated by pneumatic muscles
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=67650700780&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60147
_version_ 1681425382160465920