Impedance measurement system simulation for trapped cell model in various microwell geometries

© Published under licence by IOP Publishing Ltd. Single cell analysis is a measurement or detection of individual cell properties and responses. The method is of significance due to stimulated responses of any individual cell are different depending on their morphology and functionality. Therefore,...

Full description

Saved in:
Bibliographic Details
Main Authors: Sorawit Sanin, Chupong Pakpum, Nirut Pussadee
Format: Conference Proceeding
Published: 2020
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85077810341&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/68076
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-68076
record_format dspace
spelling th-cmuir.6653943832-680762020-04-02T15:18:13Z Impedance measurement system simulation for trapped cell model in various microwell geometries Sorawit Sanin Chupong Pakpum Nirut Pussadee Physics and Astronomy © Published under licence by IOP Publishing Ltd. Single cell analysis is a measurement or detection of individual cell properties and responses. The method is of significance due to stimulated responses of any individual cell are different depending on their morphology and functionality. Therefore, detected properties from a group of cells cannot be used to represent that of the individual cell. Since cells can move freely in a microfluidic system, a trap must be added to the system to fix the cell position at the detection region for long period observation and assay. One of the most popular used cell trap in the biomedical field is a microwell array. A sensitive technique for measuring single cell properties is an impedance measurement, in which small change in electrical properties of the cell and the surrounding medium between excitation and pick-up electrodes is recorded. However, the microwell placed between two electrodes acts as an electrical insulator to reduce the signal passing through the system. This paper focuses on the effect of microwell geometry parameters generated from the design of experiments (DOE) software on detected signals using finite element simulation software. The study found that the microwell wall thickness affects the detected current signal most significantly and the optimized geometry that minimally reduces measured current signal was 20 m height, 5 m well thickness, and 16 m gap size. 2020-04-02T15:18:13Z 2020-04-02T15:18:13Z 2019-12-16 Conference Proceeding 17426596 17426588 2-s2.0-85077810341 10.1088/1742-6596/1380/1/012116 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85077810341&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/68076
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Physics and Astronomy
spellingShingle Physics and Astronomy
Sorawit Sanin
Chupong Pakpum
Nirut Pussadee
Impedance measurement system simulation for trapped cell model in various microwell geometries
description © Published under licence by IOP Publishing Ltd. Single cell analysis is a measurement or detection of individual cell properties and responses. The method is of significance due to stimulated responses of any individual cell are different depending on their morphology and functionality. Therefore, detected properties from a group of cells cannot be used to represent that of the individual cell. Since cells can move freely in a microfluidic system, a trap must be added to the system to fix the cell position at the detection region for long period observation and assay. One of the most popular used cell trap in the biomedical field is a microwell array. A sensitive technique for measuring single cell properties is an impedance measurement, in which small change in electrical properties of the cell and the surrounding medium between excitation and pick-up electrodes is recorded. However, the microwell placed between two electrodes acts as an electrical insulator to reduce the signal passing through the system. This paper focuses on the effect of microwell geometry parameters generated from the design of experiments (DOE) software on detected signals using finite element simulation software. The study found that the microwell wall thickness affects the detected current signal most significantly and the optimized geometry that minimally reduces measured current signal was 20 m height, 5 m well thickness, and 16 m gap size.
format Conference Proceeding
author Sorawit Sanin
Chupong Pakpum
Nirut Pussadee
author_facet Sorawit Sanin
Chupong Pakpum
Nirut Pussadee
author_sort Sorawit Sanin
title Impedance measurement system simulation for trapped cell model in various microwell geometries
title_short Impedance measurement system simulation for trapped cell model in various microwell geometries
title_full Impedance measurement system simulation for trapped cell model in various microwell geometries
title_fullStr Impedance measurement system simulation for trapped cell model in various microwell geometries
title_full_unstemmed Impedance measurement system simulation for trapped cell model in various microwell geometries
title_sort impedance measurement system simulation for trapped cell model in various microwell geometries
publishDate 2020
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85077810341&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/68076
_version_ 1681426753427341312