PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)

Acrylamide is a chemical contaminant can be formed due to heating process of common foods such as roasting process of coffee bean. The aim of this research was to obtain a valid analytical method for determination of acrylamide in caffee-containing beverages by means of HPLC. An isocratic HPLC sys...

Full description

Saved in:
Bibliographic Details
Main Author: Putri Damai Ria Manurung, Margareth
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/40439
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:40439
spelling id-itb.:404392019-07-02T13:54:32ZPENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT) Putri Damai Ria Manurung, Margareth Indonesia Final Project acrylamide, coffee and high performance liquid chromatograpy INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/40439 Acrylamide is a chemical contaminant can be formed due to heating process of common foods such as roasting process of coffee bean. The aim of this research was to obtain a valid analytical method for determination of acrylamide in caffee-containing beverages by means of HPLC. An isocratic HPLC system consists of mobile phase of 30 mM phosphate buffer pH 2.5 (contains 5% of acetonitrile) - acetonitrile mixture (97.5:2.5), UV/VIS detector at 210 nm and flow rate 0.5 mL/minute, was applied. System suitability test resulted in capacity factor of 3.05, relative standard deviation (RSD) of area under the curve (AUC) and retention time (RT) of respectively, 0.8 and 0.2 %, resolution factor (Rs) of 4.86, peak tailing factor of 1.30, as well as theoretical plate number (N) of 10,671. A calibration curve in the range of 0.5 to 3.5 ppm was linear with the reqresion equation of y = 239058x + 700.33 and the correlation coefficient (r) of 0,999 as well as the relative procedural standard deviation (VX0) of 0.74%. Prior the determination, the matrix was removed by addition of anhydrous CuSO4 followed by centrifugation and extraction with n-hexane to remove the fat and oil. The limit of quantification (LOQ) and limit of detection (LOD) of this method were 0.11 and 0.04 ppm, respectively, while its percent of recoveries were in the range of 86.85 –125.49 %. The RSD of within- and inter-day determinations were in the range of 3.85 - 12.62% and 9.21 - 11.83%, respectively. The five commercial samples contain acrylamide in the range of 9.02 to 31.05 ppm. Based on overall results, it was concluded that the HPLC method was successfully developed and validated and can be applied for determination acrylamide in commercial coffee-containing beverages text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Acrylamide is a chemical contaminant can be formed due to heating process of common foods such as roasting process of coffee bean. The aim of this research was to obtain a valid analytical method for determination of acrylamide in caffee-containing beverages by means of HPLC. An isocratic HPLC system consists of mobile phase of 30 mM phosphate buffer pH 2.5 (contains 5% of acetonitrile) - acetonitrile mixture (97.5:2.5), UV/VIS detector at 210 nm and flow rate 0.5 mL/minute, was applied. System suitability test resulted in capacity factor of 3.05, relative standard deviation (RSD) of area under the curve (AUC) and retention time (RT) of respectively, 0.8 and 0.2 %, resolution factor (Rs) of 4.86, peak tailing factor of 1.30, as well as theoretical plate number (N) of 10,671. A calibration curve in the range of 0.5 to 3.5 ppm was linear with the reqresion equation of y = 239058x + 700.33 and the correlation coefficient (r) of 0,999 as well as the relative procedural standard deviation (VX0) of 0.74%. Prior the determination, the matrix was removed by addition of anhydrous CuSO4 followed by centrifugation and extraction with n-hexane to remove the fat and oil. The limit of quantification (LOQ) and limit of detection (LOD) of this method were 0.11 and 0.04 ppm, respectively, while its percent of recoveries were in the range of 86.85 –125.49 %. The RSD of within- and inter-day determinations were in the range of 3.85 - 12.62% and 9.21 - 11.83%, respectively. The five commercial samples contain acrylamide in the range of 9.02 to 31.05 ppm. Based on overall results, it was concluded that the HPLC method was successfully developed and validated and can be applied for determination acrylamide in commercial coffee-containing beverages
format Final Project
author Putri Damai Ria Manurung, Margareth
spellingShingle Putri Damai Ria Manurung, Margareth
PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
author_facet Putri Damai Ria Manurung, Margareth
author_sort Putri Damai Ria Manurung, Margareth
title PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
title_short PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
title_full PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
title_fullStr PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
title_full_unstemmed PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
title_sort pengembangan dan validasi metode penentuan kadar akrilamida pada minuman kopi cair menggunakan kromatografi cair kinerja tinggi (kckt)
url https://digilib.itb.ac.id/gdl/view/40439
_version_ 1822925751960207360