PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
Acrylamide is a chemical contaminant can be formed due to heating process of common foods such as roasting process of coffee bean. The aim of this research was to obtain a valid analytical method for determination of acrylamide in caffee-containing beverages by means of HPLC. An isocratic HPLC sys...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/40439 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:40439 |
---|---|
spelling |
id-itb.:404392019-07-02T13:54:32ZPENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT) Putri Damai Ria Manurung, Margareth Indonesia Final Project acrylamide, coffee and high performance liquid chromatograpy INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/40439 Acrylamide is a chemical contaminant can be formed due to heating process of common foods such as roasting process of coffee bean. The aim of this research was to obtain a valid analytical method for determination of acrylamide in caffee-containing beverages by means of HPLC. An isocratic HPLC system consists of mobile phase of 30 mM phosphate buffer pH 2.5 (contains 5% of acetonitrile) - acetonitrile mixture (97.5:2.5), UV/VIS detector at 210 nm and flow rate 0.5 mL/minute, was applied. System suitability test resulted in capacity factor of 3.05, relative standard deviation (RSD) of area under the curve (AUC) and retention time (RT) of respectively, 0.8 and 0.2 %, resolution factor (Rs) of 4.86, peak tailing factor of 1.30, as well as theoretical plate number (N) of 10,671. A calibration curve in the range of 0.5 to 3.5 ppm was linear with the reqresion equation of y = 239058x + 700.33 and the correlation coefficient (r) of 0,999 as well as the relative procedural standard deviation (VX0) of 0.74%. Prior the determination, the matrix was removed by addition of anhydrous CuSO4 followed by centrifugation and extraction with n-hexane to remove the fat and oil. The limit of quantification (LOQ) and limit of detection (LOD) of this method were 0.11 and 0.04 ppm, respectively, while its percent of recoveries were in the range of 86.85 –125.49 %. The RSD of within- and inter-day determinations were in the range of 3.85 - 12.62% and 9.21 - 11.83%, respectively. The five commercial samples contain acrylamide in the range of 9.02 to 31.05 ppm. Based on overall results, it was concluded that the HPLC method was successfully developed and validated and can be applied for determination acrylamide in commercial coffee-containing beverages text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Acrylamide is a chemical contaminant can be formed due to heating process of common foods such as
roasting process of coffee bean. The aim of this research was to obtain a valid analytical method for
determination of acrylamide in caffee-containing beverages by means of HPLC. An isocratic HPLC system
consists of mobile phase of 30 mM phosphate buffer pH 2.5 (contains 5% of acetonitrile) - acetonitrile
mixture (97.5:2.5), UV/VIS detector at 210 nm and flow rate 0.5 mL/minute, was applied. System
suitability test resulted in capacity factor of 3.05, relative standard deviation (RSD) of area under the
curve (AUC) and retention time (RT) of respectively, 0.8 and 0.2 %, resolution factor (Rs) of 4.86, peak
tailing factor of 1.30, as well as theoretical plate number (N) of 10,671. A calibration curve in the range
of 0.5 to 3.5 ppm was linear with the reqresion equation of y = 239058x + 700.33 and the correlation
coefficient (r) of 0,999 as well as the relative procedural standard deviation (VX0) of 0.74%. Prior the
determination, the matrix was removed by addition of anhydrous CuSO4 followed by centrifugation and
extraction with n-hexane to remove the fat and oil. The limit of quantification (LOQ) and limit of
detection (LOD) of this method were 0.11 and 0.04 ppm, respectively, while its percent of recoveries
were in the range of 86.85 –125.49 %. The RSD of within- and inter-day determinations were in the
range of 3.85 - 12.62% and 9.21 - 11.83%, respectively. The five commercial samples contain acrylamide
in the range of 9.02 to 31.05 ppm. Based on overall results, it was concluded that the HPLC method was
successfully developed and validated and can be applied for determination acrylamide in commercial
coffee-containing beverages
|
format |
Final Project |
author |
Putri Damai Ria Manurung, Margareth |
spellingShingle |
Putri Damai Ria Manurung, Margareth PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT) |
author_facet |
Putri Damai Ria Manurung, Margareth |
author_sort |
Putri Damai Ria Manurung, Margareth |
title |
PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT) |
title_short |
PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT) |
title_full |
PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT) |
title_fullStr |
PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT) |
title_full_unstemmed |
PENGEMBANGAN DAN VALIDASI METODE PENENTUAN KADAR AKRILAMIDA PADA MINUMAN KOPI CAIR MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI (KCKT) |
title_sort |
pengembangan dan validasi metode penentuan kadar akrilamida pada minuman kopi cair menggunakan kromatografi cair kinerja tinggi (kckt) |
url |
https://digilib.itb.ac.id/gdl/view/40439 |
_version_ |
1822925751960207360 |