Investigation of via2 chain test structure high resistance failure
This report covers an investigation into the failure mechanism behind the via resistance failure in an electrical test structure. Intermittent high resistance failures occur in the via 2 chain test structure for a certain process. The failed wafers showed marginally high resistance at max 4 ohm/via...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Theses and Dissertations |
Published: |
2008
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/3397 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
id |
sg-ntu-dr.10356-3397 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-33972023-07-04T15:21:04Z Investigation of via2 chain test structure high resistance failure Tan, Tze Han. School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Microelectronics This report covers an investigation into the failure mechanism behind the via resistance failure in an electrical test structure. Intermittent high resistance failures occur in the via 2 chain test structure for a certain process. The failed wafers showed marginally high resistance at max 4 ohm/via (max specification: 1.2 ohm/via). Master of Science (Microelectronics) 2008-09-17T09:29:17Z 2008-09-17T09:29:17Z 2002 2002 Thesis http://hdl.handle.net/10356/3397 Nanyang Technological University application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
topic |
DRNTU::Engineering::Electrical and electronic engineering::Microelectronics |
spellingShingle |
DRNTU::Engineering::Electrical and electronic engineering::Microelectronics Tan, Tze Han. Investigation of via2 chain test structure high resistance failure |
description |
This report covers an investigation into the failure mechanism behind the via resistance failure in an electrical test structure. Intermittent high resistance failures occur in the via 2 chain test structure for a certain process. The failed wafers showed marginally high resistance at max 4 ohm/via (max specification: 1.2 ohm/via). |
author2 |
School of Electrical and Electronic Engineering |
author_facet |
School of Electrical and Electronic Engineering Tan, Tze Han. |
format |
Theses and Dissertations |
author |
Tan, Tze Han. |
author_sort |
Tan, Tze Han. |
title |
Investigation of via2 chain test structure high resistance failure |
title_short |
Investigation of via2 chain test structure high resistance failure |
title_full |
Investigation of via2 chain test structure high resistance failure |
title_fullStr |
Investigation of via2 chain test structure high resistance failure |
title_full_unstemmed |
Investigation of via2 chain test structure high resistance failure |
title_sort |
investigation of via2 chain test structure high resistance failure |
publishDate |
2008 |
url |
http://hdl.handle.net/10356/3397 |
_version_ |
1772825476259119104 |