Inductive Coupled In-Circuit Impedance Monitoring of Electrical System Using Two-Port ABCD Network Approach
By treating the inductive coupling probes and the electrical system to be monitored as three cascaded two-port ABCD networks, the in-circuit impedance of the electrical system can be extracted with ease. The proposed method simplifies the setup calibration and allows real-time impedance monitori...
Saved in:
Main Authors: | Li, Kang Rong, See, Kye Yak, Li, Xing Ming |
---|---|
Other Authors: | School of Electrical and Electronic Engineering |
Format: | Article |
Language: | English |
Published: |
2016
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/81596 http://hdl.handle.net/10220/39556 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
Similar Items
-
Inductively coupled on-line impedance measurement for condition monitoring of electrical equipment
by: Rathnayaka, Sooriya Bandara, et al.
Published: (2018) -
Multiport conversions and cascading for h and ABCD parameters
by: Xiong, Haoyu
Published: (2024) -
Time-variant in-circuit impedance monitoring based on the inductive coupling method
by: Zhao, Zhenyu, et al.
Published: (2019) -
A wideband compact broadside coupler-based impedance transformer with 6:1 bandwidth
by: Lu, W.J., et al.
Published: (2014) -
Compact equivalent circuit model of two-layer spiral inductors
by: Pan, S.J., et al.
Published: (2014)