ENERGY OPTIMIZATION MODELING OF GEOTHERMAL POWER PLANT (CASE STUDY : DARAJAT GEOTHERMAL FIELD UNIT III, PT. CHEVRON GEOTHERMAL INDONESIA)

Darajat unit III geothermal power plant is one of the power plant which is developed by PT. Chevron Geothermal Indonesia (CGI). The power plant has capacity 121 MW on load 110%. The greatest utilization power is consumed by <br /> <br /> <br /> hot well pump and cooling tower fan...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: H.M.S. (NIM : 22611008); Pembimbing : Dr. Ir. Prihadi Setyo Darmanto, RIZAL
التنسيق: Theses
اللغة:Indonesia
الوصول للمادة أونلاين:https://digilib.itb.ac.id/gdl/view/20467
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
المؤسسة: Institut Teknologi Bandung
اللغة: Indonesia
id id-itb.:20467
spelling id-itb.:204672017-09-27T15:06:47ZENERGY OPTIMIZATION MODELING OF GEOTHERMAL POWER PLANT (CASE STUDY : DARAJAT GEOTHERMAL FIELD UNIT III, PT. CHEVRON GEOTHERMAL INDONESIA) H.M.S. (NIM : 22611008); Pembimbing : Dr. Ir. Prihadi Setyo Darmanto, RIZAL Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/20467 Darajat unit III geothermal power plant is one of the power plant which is developed by PT. Chevron Geothermal Indonesia (CGI). The power plant has capacity 121 MW on load 110%. The greatest utilization power is consumed by <br /> <br /> <br /> hot well pump and cooling tower fan. The fluctuation of wet bulb temperature provides opportunity to optimize the energy of those equipments. <br /> <br /> <br /> The optimization of utilization power of hot well pump and cooling tower fan is applied using Variable Frequency Drive (VFD) method. The modeling process <br /> <br /> <br /> was done by using Engineering Equation Solver (EES) commercial version 9.430. The model was applied on load 110%, 100% and partial load. The model was validated to the Process Flow Diagram (PFD) Darajat unit III. The result of modeling process was analized through Specific Steam Consumption (SSC) netto. The result shows that the present operation of power plant reaches its optimum condition. The application of VFD on load 110% and 100% can be applied only if the hot well pump can be operated in frequency 60 Hz. Otherwise, two kinds of VFD should be applied for partial load. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Darajat unit III geothermal power plant is one of the power plant which is developed by PT. Chevron Geothermal Indonesia (CGI). The power plant has capacity 121 MW on load 110%. The greatest utilization power is consumed by <br /> <br /> <br /> hot well pump and cooling tower fan. The fluctuation of wet bulb temperature provides opportunity to optimize the energy of those equipments. <br /> <br /> <br /> The optimization of utilization power of hot well pump and cooling tower fan is applied using Variable Frequency Drive (VFD) method. The modeling process <br /> <br /> <br /> was done by using Engineering Equation Solver (EES) commercial version 9.430. The model was applied on load 110%, 100% and partial load. The model was validated to the Process Flow Diagram (PFD) Darajat unit III. The result of modeling process was analized through Specific Steam Consumption (SSC) netto. The result shows that the present operation of power plant reaches its optimum condition. The application of VFD on load 110% and 100% can be applied only if the hot well pump can be operated in frequency 60 Hz. Otherwise, two kinds of VFD should be applied for partial load.
format Theses
author H.M.S. (NIM : 22611008); Pembimbing : Dr. Ir. Prihadi Setyo Darmanto, RIZAL
spellingShingle H.M.S. (NIM : 22611008); Pembimbing : Dr. Ir. Prihadi Setyo Darmanto, RIZAL
ENERGY OPTIMIZATION MODELING OF GEOTHERMAL POWER PLANT (CASE STUDY : DARAJAT GEOTHERMAL FIELD UNIT III, PT. CHEVRON GEOTHERMAL INDONESIA)
author_facet H.M.S. (NIM : 22611008); Pembimbing : Dr. Ir. Prihadi Setyo Darmanto, RIZAL
author_sort H.M.S. (NIM : 22611008); Pembimbing : Dr. Ir. Prihadi Setyo Darmanto, RIZAL
title ENERGY OPTIMIZATION MODELING OF GEOTHERMAL POWER PLANT (CASE STUDY : DARAJAT GEOTHERMAL FIELD UNIT III, PT. CHEVRON GEOTHERMAL INDONESIA)
title_short ENERGY OPTIMIZATION MODELING OF GEOTHERMAL POWER PLANT (CASE STUDY : DARAJAT GEOTHERMAL FIELD UNIT III, PT. CHEVRON GEOTHERMAL INDONESIA)
title_full ENERGY OPTIMIZATION MODELING OF GEOTHERMAL POWER PLANT (CASE STUDY : DARAJAT GEOTHERMAL FIELD UNIT III, PT. CHEVRON GEOTHERMAL INDONESIA)
title_fullStr ENERGY OPTIMIZATION MODELING OF GEOTHERMAL POWER PLANT (CASE STUDY : DARAJAT GEOTHERMAL FIELD UNIT III, PT. CHEVRON GEOTHERMAL INDONESIA)
title_full_unstemmed ENERGY OPTIMIZATION MODELING OF GEOTHERMAL POWER PLANT (CASE STUDY : DARAJAT GEOTHERMAL FIELD UNIT III, PT. CHEVRON GEOTHERMAL INDONESIA)
title_sort energy optimization modeling of geothermal power plant (case study : darajat geothermal field unit iii, pt. chevron geothermal indonesia)
url https://digilib.itb.ac.id/gdl/view/20467
_version_ 1823633586973048832