Laser focus depth adaptation for decapsulation of copper wirebonded devices
Although pre-laser decapsulation reduces the time to acid exposure for subsequent chemical decapsulation of copper wirebonded devices, it can result in severely damaged or broken copper wirebonds if carried out at a focused depth followed by chemical decapsulation. Thin quad flat packages (TQFP...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2015
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/107318 http://hdl.handle.net/10220/25336 http://www.asminternational.org/web/edfas/technical?p_p_auth=ob3PcFz5&p_p_id=101&p_p_lifecycle=0&p_p_state=maximized&_101_struts_action=%2Fasset_publisher%2Fview_content&_101_assetEntryId=22674956&_101_type=content&_101_groupId=10192&_101_urlTitle=laser-focus-depth-adaptation-for-decapsulation-of-copper-wirebonded-devices |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
Summary: | Although pre-laser decapsulation reduces the time to acid
exposure for subsequent chemical decapsulation of copper
wirebonded devices, it can result in severely damaged or
broken copper wirebonds if carried out at a focused depth
followed by chemical decapsulation. Thin quad flat packages
(TQFPs) of dimensions 22 mm × 22 mm, with copper
wirebonds were pre-laser decapped (Nd:YAG laser, 1064 nm)
at three depths of focus, at focus, (z-0.5) mm and (z-1) mm.
Reducing the laser focus depth by 1 mm, followed by subsequent chemical decapsulation, resulted in the least damage to copper wirebonds. Average percentage reduction in
copper wirebond diameter after complete (laser and chemical)
decapsulation is about 2.30%. |
---|