Development of a mechanical setup for assessing stiffness of the wrist joints with 3 DOF of motion (A037)

The objective of this project is to design and develop a fully mechanical contraption for assessing the stiffness of human wrist joints. The previous designs have attached torque motors at each point of rotation and had 2 DOF. The primary aim of this project is to design a new setup with 3 DOF that...

Full description

Saved in:
Bibliographic Details
Main Author: Lee, Jyun
Other Authors: Domenico Campolo
Format: Final Year Project
Language:English
Published: 2015
Subjects:
Online Access:http://hdl.handle.net/10356/64583
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-64583
record_format dspace
spelling sg-ntu-dr.10356-645832023-03-04T18:56:49Z Development of a mechanical setup for assessing stiffness of the wrist joints with 3 DOF of motion (A037) Lee, Jyun Domenico Campolo School of Mechanical and Aerospace Engineering Robotics Research Centre DRNTU::Engineering::Mechanical engineering The objective of this project is to design and develop a fully mechanical contraption for assessing the stiffness of human wrist joints. The previous designs have attached torque motors at each point of rotation and had 2 DOF. The primary aim of this project is to design a new setup with 3 DOF that is inertially balanced at all positions. In order to effectively measure slow and fast perturbation without having the weight of the setup affect the stiffness of the human wrist, this inertially balanced setup is required. Validation tests for static and continuous perturbation in flexion-extension are examined. Pronation-Supination is also examined as the 3rd DOF while Radial-Ulnar deviation are also included in the measurements. Because the dynamics of wrist rotations are dominated by stiffness, understanding wrist rotations requires a thorough characterization of wrist stiffness in multiple degrees of freedom. The only prior measurement of multivariable wrist stiffness was confined to approximately one-seventh of the wrist range of motion (ROM). Here, we present a precise nonlinear characterization of passive wrist joint stiffness over a range three times greater, which covers approximately 70% of the functional ROM of the wrist. Bachelor of Engineering (Mechanical Engineering) 2015-05-28T07:17:44Z 2015-05-28T07:17:44Z 2015 2015 Final Year Project (FYP) http://hdl.handle.net/10356/64583 en Nanyang Technological University 45 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering
spellingShingle DRNTU::Engineering::Mechanical engineering
Lee, Jyun
Development of a mechanical setup for assessing stiffness of the wrist joints with 3 DOF of motion (A037)
description The objective of this project is to design and develop a fully mechanical contraption for assessing the stiffness of human wrist joints. The previous designs have attached torque motors at each point of rotation and had 2 DOF. The primary aim of this project is to design a new setup with 3 DOF that is inertially balanced at all positions. In order to effectively measure slow and fast perturbation without having the weight of the setup affect the stiffness of the human wrist, this inertially balanced setup is required. Validation tests for static and continuous perturbation in flexion-extension are examined. Pronation-Supination is also examined as the 3rd DOF while Radial-Ulnar deviation are also included in the measurements. Because the dynamics of wrist rotations are dominated by stiffness, understanding wrist rotations requires a thorough characterization of wrist stiffness in multiple degrees of freedom. The only prior measurement of multivariable wrist stiffness was confined to approximately one-seventh of the wrist range of motion (ROM). Here, we present a precise nonlinear characterization of passive wrist joint stiffness over a range three times greater, which covers approximately 70% of the functional ROM of the wrist.
author2 Domenico Campolo
author_facet Domenico Campolo
Lee, Jyun
format Final Year Project
author Lee, Jyun
author_sort Lee, Jyun
title Development of a mechanical setup for assessing stiffness of the wrist joints with 3 DOF of motion (A037)
title_short Development of a mechanical setup for assessing stiffness of the wrist joints with 3 DOF of motion (A037)
title_full Development of a mechanical setup for assessing stiffness of the wrist joints with 3 DOF of motion (A037)
title_fullStr Development of a mechanical setup for assessing stiffness of the wrist joints with 3 DOF of motion (A037)
title_full_unstemmed Development of a mechanical setup for assessing stiffness of the wrist joints with 3 DOF of motion (A037)
title_sort development of a mechanical setup for assessing stiffness of the wrist joints with 3 dof of motion (a037)
publishDate 2015
url http://hdl.handle.net/10356/64583
_version_ 1759854265825755136